Recent work

Electrical projects in Sydney's Eastern Suburbs

Photos from Peter's own jobs. Tap or click any photo to enlarge it, then use the arrows to move through the rest.

On the job: preparing a ceiling for a projector

Peter's own video from a job in October 2025. In his words: reinforcement for the projector mount; the cables, two Cat6 and an HDMI, plus 2.5 mm TPS for a power point; and opening up the ceiling space to bring the cables in.

Peter's video from the job (0:40). It plays when you tap it.

In short

These 17 photos are from Ambient Electrical jobs done by Peter Stafford: switchboard upgrades and metering, feature lighting and chandeliers, pool and garden lighting, outdoor power and security cameras, and fault finding. Every job is done by Peter himself, with no sub-contractors. The photos show the work, not a particular suburb.

Recent jobs, written up

LED strip lighting in a renovated Rose Bay bathroom, on a motion sensor

When
October 2026
Where
Rose Bay
Service
LED lighting

The problem: A recently renovated bathroom in Rose Bay needed LED strip lighting that switches on by itself.

What Peter did:

  • Added LED COB strip lighting to the bathroom
  • Connected it to a motion sensor, for automatic activation

The result: LED strip lighting in the renovated bathroom, controlled by a motion sensor.

Adding LED COB strip to this recently renovated bathroom in Rose Bay. Lighting controlled by a motion sensor for automatic activation.

Peter Stafford

EV charger installation in Bondi Junction, on a new 32 amp circuit

When
October 2026
Where
Bondi Junction
Service
EV chargers

The problem: The EV charger needed a new 32 amp circuit, and the cable had to reach it without spoiling the look of the property's frontage.

What Peter did:

  • Installed a new 32 amp circuit for the EV charger
  • Ran the cable through the wall cavity, so it does not affect the look of the property's frontage

The result: An Ocular wall charger on its own 32 amp circuit, with its cable hidden in the wall cavity.

The EV charger required a new 32Amp circuit. Cable was installed via the cavity so as to not affect the aesthetics of the property frontage

Peter Stafford
An electric car charging on a paved driveway from the wall charger at the side of the house
Charging from the new wall charger, Bondi Junction

Eglo Surf ceiling fan with light in a Clovelly master bedroom

When
October 2026
Where
Clovelly
Service
Ceiling fans

The problem: The master bedroom had an old oyster light fitting.

What Peter did:

  • Took down the old oyster light fitting
  • Installed an Eglo Surf ceiling fan with a built-in light in its place

The result: The master bedroom now has a ceiling fan with its own light, in place of the old oyster fitting.

A white three-blade Eglo Surf ceiling fan with a built-in light, in a bedroom with ocean views
Ceiling fan with a light, replacing an old oyster fitting

Ausgrid defect notice in Bellevue Hill: meter box replaced

When
October 2026
Where
Bellevue Hill
Service
Switchboard upgrades

The problem: Ausgrid issued a defect notice for an earth fault and a service fuse defect.

What Peter did:

  • Replaced the meter box completely
  • Rectified the external wall

The result: A complete new meter box and a rectified external wall, as the defect notice required.

An old meter box with two analogue meters, an old fuse unit and a red warning tag, above a newer circuit-breaker board
The old meter box before it was replaced

Emergency callout: three-phase main switch fault in Double Bay

When
October 2026
Where
Double Bay
Service
Electrical faults

The problem: The three-phase isolator on a sub-board upstairs, which controls the oven and power circuits, was not working properly.

What Peter did:

  • Tested the 32 A three-phase main switch in the main switch room, on its supply side and its load side
  • Supply side: 415 volts between every pair of phases, as it should be
  • Load side: 415 volts between two of the phases, but 240 volts across the other two pairs, where 415 should be
  • Found no continuity through the main switch on the third phase (the blue cable)

The result: The fault was in the main switch downstairs, not the sub-board upstairs. The fix is to replace it with a new 32 A three-phase main switch from a reputable brand.

My recommendation, folks, is to stay with the reputable brands.

Peter Stafford

Watch Peter's video of the job

Switchboards and metering

Switchboard Upgrades

Lighting and chandeliers

Lighting Installation and Design

Pool and garden lighting

Pool Light Replacement

Outdoor, power and security

Power Point Installation

Faults, cabling and assessments

Electrical Fault Finding